Fully automated coagulation analyzer SF-8200 adopts clotting and immunoturbidimetry, chromogenic method to test the clotting of plasma. The instrument shows that clotting measurement value is the clotting time (in seconds).
The principle of clotting test consists in measuring the variation in amplitude of the ball oscillation. A drop in amplitude corresponds to an increase in the viscosity of the medium. The instrument can figure out the clotting time by the motion of the ball.
1. Designed for Large-level Lab.
2. Viscosity based (Mechanical clotting) assay, immunoturbidimetric assay, chromogenic assay.
3. Internal barcode of sample and reagent, LIS support.
4. Original reagents, cuvettes and solution for better results.
5. Cap-piercing optional.
1) Testing Method | Viscosity based Clotting method, immunoturbidimetric assay, chromogenic assay. |
2) Parameters | PT, APTT, TT, FIB, D-Dimer, FDP, AT-Ⅲ, Protein C, Protein S, LA, Factors. |
3) Probe | 2 separate probes. |
Sample probe | with Liquid sensor function. |
Reagent probe | with Liquid sensor function and Instantly heating function. |
4) Cuvettes | 1000 cuvettes/ load, with continuous loading. |
5) TAT | Emergency testing on any position. |
6) Sample position | 6*10 sample rack with automatic lock function.Internal barcode reader. |
7) Testing Position | 8 channels. |
8) Reagent Position | 42 positions, contain 16℃ and stirring positions.Internal barcode reader. |
9) Incubation Position | 20 positions with 37℃. |
10) Data Transmission | Bidirectional communication, HIS/LIS network. |
11) Safety | Close-cover protection for Operator safety. |
1.Multiple Test Methods
•Clotting (Mechanical viscosity based), chromogenic,Turbidimetric
•No interference from intems, hemolysis, chills and turbid particles;
•Multiple wavelength compatible for various test including D-Dimer, FDP and AT-ll,Lupus, Factors, Protein C, Protein S, etc.;
•8 independent test channels with random and parallel tests.
2. Intelligent Operation System
•Independent sample and reagent probe; higher throughput and efficiency.
•1000 continuous cuvettes simplify operation and increase lab efficiency;
•Automatic enable and switch of reagent backup function;
•Automatic retest and re-dilute for abnormal sample;
•Alarm for insufficient consumables overflow;
•Automatic probe cleaning. avoids from cross-contamination.
•High-speed 37′C pre-heating with automatic temperature control.
3 .Reagents and Consumables Management
•Reagent Barcode reader intelligent recognition of reagent type and position.
•Reagent position with room temperature, cooling and stir function:
•Smart reagent barcode ,reagent lot number, expiration date, calibration curve and other information recorded automatically
4.Intelligent Sample Management
•Drawer-type designed sample rack; support original tube.
•Position detection, auto lock, and indicator light of sample rack.
•Random emergency position; support priority of emergency.
•Sample barcode reader; dual LIS/HIS supported.
Used for measuring prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB) index, thrombin time (TT), AT, FDP, D-Dimer, Factors, Protein C, Protein S, etc…